Receiver transient support time calculator

The isothermal usable air inventory supports only the demand exceeding continuing compressor supply. The supply must be lower than the burst demand.

Units
t=V×(Phi−Plo)Patm×(Qd−Qs)t = \frac{V \times \left(P_{\text{hi}} - P_{\text{lo}}\right)}{P_{\text{atm}} \times \left(Q_{d} - Q_{s}\right)}

Calculator

Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.

ft³
psig
psig
psia
cfm
cfm
min

Worked example

Given

  • VV = 120 ft³
  • PhiP_{\text{hi}} = 120 psig
  • PloP_{\text{lo}} = 90 psig
  • PatmP_{\text{atm}} = 14.7 psia
  • QdQ_{d} = 700 cfm
  • QsQ_{s} = 450 cfm
t=120×(120−90)14.7×(700−450)≈0.9796t = \frac{120 \times \left(120 - 90\right)}{14.7 \times \left(700 - 450\right)} \approx 0.9796

Symbols and units

SymbolMeaningUnit
ttsupport timemin
VVreceiver geometric volumeft³
PhiP_{\text{hi}}initial receiver pressurepsig
PloP_{\text{lo}}minimum receiver pressurepsig
PatmP_{\text{atm}}reference atmospheric pressurepsia
QdQ_{d}free-air transient demandcfm
QsQ_{s}continuing free-air supplycfm