Receiver transient support time calculator
Receiver transient support time
The isothermal usable air inventory supports only the demand exceeding continuing compressor supply. The supply must be lower than the burst demand.
Units
t=Patm×(Qd−Qs)V×(Phi−Plo)
t=Patm×(Qd−Qs)1000×V×(Phi−Plo)
Calculator
Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.
Worked example
Given
- V = 120 ft³
- Phi = 120 psig
- Plo = 90 psig
- Patm = 14.7 psia
- Qd = 700 cfm
- Qs = 450 cfm
t=14.7×(700−450)120×(120−90)≈0.9796
Given
- V = 3 m³
- Phi = 820 kPa gauge
- Plo = 610 kPa gauge
- Patm = 101.325 kPa absolute
- Qd = 300 L/s
- Qs = 190 L/s
t=101.325×(300−190)1000×3×(820−610)≈56.524
Symbols and units
| Symbol | Meaning | Unit |
| t | support time | min |
| V | receiver geometric volume | ft³ |
| Phi | initial receiver pressure | psig |
| Plo | minimum receiver pressure | psig |
| Patm | reference atmospheric pressure | psia |
| Qd | free-air transient demand | cfm |
| Qs | continuing free-air supply | cfm |
| Symbol | Meaning | Unit |
| t | support time | s |
| V | receiver geometric volume | m³ |
| Phi | initial receiver pressure | kPa gauge |
| Plo | minimum receiver pressure | kPa gauge |
| Patm | reference atmospheric pressure | kPa absolute |
| Qd | free-air transient demand | L/s |
| Qs | continuing free-air supply | L/s |
Results are estimates for study and screening. Check the inputs, units and assumptions before you use them for design, billing or contract decisions.