ClueLuma

Dust-control electric savings calculator

Equivalent full-power avoided hours are a case-specific simplification.

Units
Se=hp×0.746ηm×Δhday×days×ceS_{e} = \frac{\text{hp} \times 0.746}{\eta_{m}} \times {\Delta h_{\text{day}}} \times \text{days} \times c_{e}

Calculator

Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.

hp
fraction
h/day
day/yr
$/kWh
$/yr

Worked example

Given

  • hp\text{hp} = 55 hp
  • ηm\eta_{m} = 0.89 fraction
  • Δhday{\Delta h_{\text{day}}} = 3.2 h/day
  • days\text{days} = 235 day/yr
  • cec_{e} = 0.13 $/kWh
Se=55×0.7460.89×3.2×235×0.13≈4,507S_{e} = \frac{55 \times 0.746}{0.89} \times 3.2 \times 235 \times 0.13 \approx 4{,}507

Symbols and units

SymbolMeaningUnit
SeS_{e}annual electric savings$/yr
hp\text{hp}motor shaft horsepowerhp
ηm\eta_{m}motor efficiencyfraction
Δhday{\Delta h_{\text{day}}}equivalent daily motor hours avoidedh/day
days\text{days}annual production daysday/yr
cec_{e}energy price$/kWh

Related calculators

Results are estimates for study and screening. Check the inputs, units and assumptions before you use them for design, billing or contract decisions.