Saturated wet-steam quality calculator
Saturated wet-steam quality
For an equilibrium saturated liquid-vapor mixture, h = h_f + x_fraction × h_fg; quality measures vapor mass fraction, not vapor volume.
Units
Calculator
Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.
Worked example
Given
- = 980 Btu/lb
- = 260 Btu/lb
- = 900 Btu/lb
Given
- = 2,200 kJ/kg
- = 600 kJ/kg
- = 2,100 kJ/kg
Symbols and units
| Symbol | Meaning | Unit |
|---|---|---|
| steam mass quality | % | |
| wet-stream specific enthalpy | Btu/lb | |
| saturated liquid enthalpy at the same pressure | Btu/lb | |
| latent heat at the same pressure | Btu/lb |
| Symbol | Meaning | Unit |
|---|---|---|
| steam mass quality | % | |
| wet-stream specific enthalpy | kJ/kg | |
| saturated liquid enthalpy at the same pressure | kJ/kg | |
| latent heat at the same pressure | kJ/kg |
Related calculators
Results are estimates for study and screening. Check the inputs, units and assumptions before you use them for design, billing or contract decisions.