ClueLuma

Annual steam-leak cost calculator

Value leak mass with consistent steam energy, hours and tariff units.

Units
Cyear=m˙leak×Δh×H×rMMBtu1,000,000C_{\text{year}} = \frac{\dot{m}_{\text{leak}} \times \Delta h \times H \times r_{\text{MMBtu}}}{1{,}000{,}000}

Calculator

Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.

lb/h
Btu/lb
h/year
$/MMBtu
$/year

Worked example

Given

  • m˙leak\dot{m}_{\text{leak}} = 72 lb/h
  • Δh\Delta h = 1,010 Btu/lb
  • HH = 6,200 h/year
  • rMMBtur_{\text{MMBtu}} = 10.8 $/MMBtu
Cyear=72×1010×6200×10.81,000,000≈4,869C_{\text{year}} = \frac{72 \times 1010 \times 6200 \times 10.8}{1{,}000{,}000} \approx 4{,}869

Symbols and units

SymbolMeaningUnit
CyearC_{\text{year}}annual steam-energy cost$/year
m˙leak\dot{m}_{\text{leak}}steam losslb/h
Δh\Delta hvalued steam enthalpy above return/reference stateBtu/lb
HHannual leaking hoursh/year
rMMBtur_{\text{MMBtu}}steam cost per million Btu$/MMBtu

Related calculators

Results are estimates for study and screening. Check the inputs, units and assumptions before you use them for design, billing or contract decisions.