ClueLuma

Quadratic curve operating flow calculator

Equate fitted pump head H_0−aQ² and system head H_static+KQ² within their valid operating range.

Units
Q=H0−Hstatica+KQ = \sqrt{\frac{H_{0} - H_{\text{static}}}{a + K}}

Calculator

Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.

ft
ft
ft/(gpm)^2
ft/(gpm)^2
gpm

Worked example

Given

  • H0H_{0} = 100 ft
  • HstaticH_{\text{static}} = 20 ft
  • aa = 0.0003 ft/(gpm)^2
  • KK = 0.0002 ft/(gpm)^2
Q=100−200.0003+0.0002=400Q = \sqrt{\frac{100 - 20}{0.0003 + 0.0002}} = 400

Symbols and units

SymbolMeaningUnit
QQoperating flowgpm
H0H_{0}pump shutoff head within fitted curveft
HstaticH_{\text{static}}system static headft
aapump-curve quadratic coefficientft/(gpm)^2
KKsystem quadratic coefficientft/(gpm)^2

Related calculators

Results are estimates for study and screening. Check the inputs, units and assumptions before you use them for design, billing or contract decisions.