Net steam-generation heat calculator
Net steam-generation heat
Subtract incoming feedwater enthalpy when measuring useful heat added to steam.
Units
quseful=msteam×(hsteam−hfeed)
quseful=msteam×(hsteam−hfeed)
Calculator
Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.
Worked example
Given
- msteam = 10,000 lb/h
- hsteam = 1,190 Btu/lb
- hfeed = 180 Btu/lb
quseful=10,000×(1190−180)=10,100,000
Given
- msteam = 1.2 kg/s
- hsteam = 2,676 kJ/kg
- hfeed = 83.8 kJ/kg
quseful=1.2×(2676−83.8)≈3,111
Symbols and units
| Symbol | Meaning | Unit |
| quseful | net steam-generation heat rate | Btu/h |
| msteam | steam mass flow | lb/h |
| hsteam | outgoing steam enthalpy | Btu/lb |
| hfeed | incoming feedwater enthalpy | Btu/lb |
| Symbol | Meaning | Unit |
| quseful | net steam-generation heat rate | kW |
| msteam | steam mass flow | kg/s |
| hsteam | outgoing steam enthalpy | kJ/kg |
| hfeed | incoming feedwater enthalpy | kJ/kg |
Results are estimates for study and screening. Check the inputs, units and assumptions before you use them for design, billing or contract decisions.