Water lost through leaked steam calculator
Water lost through leaked steam
Use latent evaporation heat consistently with the energy loss basis, not an unrelated total steam enthalpy.
Units
mwater=hfgQannual
mwater=hfg3600×Qannual
Calculator
Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.
Worked example
Given
- Qannual = 48,000,000 Btu/yr
- hfg = 960 Btu/lb
mwater=96048,000,000=50,000
Given
- Qannual = 15,000 kWh/year
- hfg = 2,257 kJ/kg
mwater=22573600×15,000≈23,926
Symbols and units
| Symbol | Meaning | Unit |
| mwater | annual mass of evaporated water lost | lb/yr |
| Qannual | annual evaporation heat attributed to lost steam | Btu/yr |
| hfg | latent heat of vaporization at steam conditions | Btu/lb |
| Symbol | Meaning | Unit |
| mwater | annual mass of evaporated water lost | kg/year |
| Qannual | annual evaporation heat attributed to lost steam | kWh/year |
| hfg | latent heat of vaporization at steam conditions | kJ/kg |
Results are estimates for study and screening. Check the inputs, units and assumptions before you use them for design, billing or contract decisions.