ClueLuma

Supplemental fuel required calculator

The supplemental fuel supplies the useful-energy deficit.

Units
Mneeded=Qdemand−Qwaste useful2000×HV×ηM_{\text{needed}} = \frac{Q_{\text{demand}} - Q_{\text{waste useful}}}{2000 \times \mathrm{HV} \times \eta}

Calculator

Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.

Btu/yr
Btu/yr
Btu/lb
—
short ton/yr

Worked example

Given

  • Qwaste usefulQ_{\text{waste useful}} = 20,000,000,000 Btu/yr
  • QdemandQ_{\text{demand}} = 60,000,000,000 Btu/yr
  • HV\mathrm{HV} = 12,000 Btu/lb
  • η\eta = 0.82 —
Mneeded=60,000,000,000−20,000,000,0002000×12,000×0.82≈2,033M_{\text{needed}} = \frac{60{,}000{,}000{,}000 - 20{,}000{,}000{,}000}{2000 \times 12{,}000 \times 0.82} \approx 2{,}033

Symbols and units

SymbolMeaningUnit
MneededM_{\text{needed}}supplemental fuel massshort ton/yr
Qwaste usefulQ_{\text{waste useful}}usable waste-fuel heatBtu/yr
QdemandQ_{\text{demand}}annual useful heat neededBtu/yr
HV\mathrm{HV}supplemental fuel heating valueBtu/lb
η\etasupplemental boiler efficiency—