Sensible heat from field airflow calculator
Sensible heat from field airflow
Use measured airflow and temperature difference to estimate sensible heat at standard air conditions.
Units
qair=1.08×Qair×ΔT
qair=1.2×Qair×ΔT
Calculator
Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.
Worked example
Given
- Qair = 2,200 cfm
- ΔT = 16 °F
qair=1.08×2200×16=38,016
Given
- Qair = 1,800 L/s
- ΔT = 12 K
qair=1.2×1800×12=25,920
Symbols and units
| Symbol | Meaning | Unit |
| qair | sensible heat rate at standard air conditions | Btu/h |
| Qair | measured air volume flow | cfm |
| ΔT | air temperature difference | °F |
| Symbol | Meaning | Unit |
| qair | sensible heat rate at standard air conditions | W |
| Qair | measured air volume flow | L/s |
| ΔT | air temperature difference | K |
Results are estimates for study and screening. Check the inputs, units and assumptions before you use them for design, billing or contract decisions.