Motor input from horsepower calculator
Motor input from horsepower
The filter and dust-control examples divide shaft power by motor efficiency.
Units
P=ηmhp×LF×0.746
P=ηmPrated×LF
Calculator
Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.
Worked example
Given
- hp = 80 hp
- LF = 0.72 fraction
- ηm = 0.91 fraction
P=0.9180×0.72×0.746≈47.219
Given
- Prated = 60 kW
- LF = 0.75 fraction
- ηm = 0.92 fraction
P=0.9260×0.75≈48.913
Symbols and units
| Symbol | Meaning | Unit |
| P | electric input | kW |
| hp | rated shaft horsepower | hp |
| LF | shaft load fraction | fraction |
| ηm | motor efficiency | fraction |
| Symbol | Meaning | Unit |
| P | electric input | kW |
| Prated | shaft power expressed as kilowatts | kW |
| LF | shaft load fraction | fraction |
| ηm | motor efficiency | fraction |
Results are estimates for study and screening. Check the inputs, units and assumptions before you use them for design, billing or contract decisions.