ClueLuma

Heat rate and electricity-energy conversion (HR) calculator

Heat rate compares fuel energy with generated electricity; net CHP allocation must be stated.

Units
HR=Efuel allocatedEelectric\mathrm{HR} = \frac{E_{\text{fuel allocated}}}{E_{\text{electric}}}

Calculator

Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.

Btu
kWh
Btu/kWh

Worked example

Given

  • Efuel allocatedE_{\text{fuel allocated}} = 760,000,000 Btu
  • EelectricE_{\text{electric}} = 80,000 kWh
HR=760,000,00080,000=9,500\mathrm{HR} = \frac{760{,}000{,}000}{80{,}000} = 9{,}500

Symbols and units

SymbolMeaningUnit
HR\mathrm{HR}fuel heat allocated per unit of electric outputBtu/kWh
Efuel allocatedE_{\text{fuel allocated}}fuel energy on the selected gross/net allocation basisBtu
EelectricE_{\text{electric}}generated electricitykWh

Related calculators