Collector area at a stated irradiance calculator
Collector area at a stated irradiance
The ideal noon calculation uses η=1; actual useful output includes efficiency.
Units
A=I×ηQ˙required
A=I×η1000×Q˙required
Calculator
Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.
Worked example
Given
- Q˙required = 67,000 Btu/h
- I = 240 Btu/(h·ft²)
- η = 0.52 fraction
A=240×0.5267,000≈536.9
Given
- Q˙required = 20 kW
- I = 750 W/m²
- η = 0.5 fraction
A=750×0.51000×20≈53.333
Symbols and units
| Symbol | Meaning | Unit |
| A | collector area | ft² |
| Q˙required | required useful heat rate | Btu/h |
| I | incident solar irradiance | Btu/(h·ft²) |
| η | collector efficiency; 1 for ideal screening | fraction |
| Symbol | Meaning | Unit |
| A | collector area | m² |
| Q˙required | required useful heat rate | kW |
| I | incident solar irradiance | W/m² |
| η | collector efficiency | fraction |
Results are estimates for study and screening. Check the inputs, units and assumptions before you use them for design, billing or contract decisions.