Capacity must cover delivered energy after the allowed discharge depth and one-way conversion loss.

Enom=Ereq×100×100DoD×ηE_{\text{nom}} = \frac{E_{\text{req}} \times 100 \times 100}{\mathrm{DoD} \times \eta}

Calculator

Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.

kWh
%
%
kWh

Worked example

Given

  • EreqE_{\text{req}} = 360 kWh
  • DoD\mathrm{DoD} = 80 %
  • η\eta = 90 %
Enom=360×100×10080×90=500E_{\text{nom}} = \frac{360 \times 100 \times 100}{80 \times 90} = 500

Symbols and units

SymbolMeaningUnit
EnomE_{\text{nom}}nameplate DC energykWh
EreqE_{\text{req}}required AC energy deliveredkWh
DoD\mathrm{DoD}permitted depth of discharge%
η\etaDC-to-AC discharge efficiency%