Required lighting power reduction calculator
Required lighting power reduction
A space-based allowance sums area times the applicable density for each space. Reduction is the positive excess of installed power; the supplied limits are scenario criteria, not a code-version claim.
Units IP (US) SI (metric)
d P = max ( P actual − A 1 × L P D 1 − A 2 × L P D 2 , 0 ) \mathit{dP} = \max\left(P_{\text{actual}} - A_{1} \times \mathrm{LPD}_{1} - A_{2} \times \mathrm{LPD}_{2},\ 0\right) dP = max ( P actual − A 1 × LPD 1 − A 2 × LPD 2 , 0 )
d P = max ( P actual − A 1 × L P D 1 − A 2 × L P D 2 , 0 ) \mathit{dP} = \max\left(P_{\text{actual}} - A_{1} \times \mathrm{LPD}_{1} - A_{2} \times \mathrm{LPD}_{2},\ 0\right) dP = max ( P actual − A 1 × LPD 1 − A 2 × LPD 2 , 0 )
Calculator
Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.
Worked example
Given
P actual P_{\text{actual}} P actual = 8,000 W A 1 A_{1} A 1 = 5,000 ft² L P D 1 \mathrm{LPD}_{1} LPD 1 = 1 W/ft² A 2 A_{2} A 2 = 3,000 ft² L P D 2 \mathrm{LPD}_{2} LPD 2 = 0.5 W/ft²
d P = max ( 8000 − 5000 × 1 − 3000 × 0.5 , 0 ) = 1 , 500 \mathit{dP} = \max\left(8000 - 5000 \times 1 - 3000 \times 0.5,\ 0\right) = 1{,}500 dP = max ( 8000 − 5000 × 1 − 3000 × 0.5 , 0 ) = 1 , 500
Given
P actual P_{\text{actual}} P actual = 7,000 W A 1 A_{1} A 1 = 500 m² L P D 1 \mathrm{LPD}_{1} LPD 1 = 8 W/m² A 2 A_{2} A 2 = 300 m² L P D 2 \mathrm{LPD}_{2} LPD 2 = 6 W/m²
d P = max ( 7000 − 500 × 8 − 300 × 6 , 0 ) = 1 , 200 \mathit{dP} = \max\left(7000 - 500 \times 8 - 300 \times 6,\ 0\right) = 1{,}200 dP = max ( 7000 − 500 × 8 − 300 × 6 , 0 ) = 1 , 200
Symbols and units
Symbol Meaning Unit
d P \mathit{dP} dP minimum installed lighting power to remove W
P actual P_{\text{actual}} P actual installed lighting input within scope W
A 1 A_{1} A 1 first eligible space area ft²
L P D 1 \mathrm{LPD}_{1} LPD 1 stipulated first-space allowance W/ft²
A 2 A_{2} A 2 second eligible space area ft²
L P D 2 \mathrm{LPD}_{2} LPD 2 stipulated second-space allowance W/ft²
Symbol Meaning Unit
d P \mathit{dP} dP minimum installed lighting power to remove W
P actual P_{\text{actual}} P actual installed lighting input within scope W
A 1 A_{1} A 1 first eligible space area m²
L P D 1 \mathrm{LPD}_{1} LPD 1 stipulated first-space allowance W/m²
A 2 A_{2} A 2 second eligible space area m²
L P D 2 \mathrm{LPD}_{2} LPD 2 stipulated second-space allowance W/m²
Studying for the CEM® exam?
The ClueLuma CEM app has 1,041 calculation-focused practice questions, a formula calculator like this one in every question, and an endless drill where the numbers change every time. Try it free, no card needed.
Results are estimates for study and screening. Check the inputs, units and assumptions before you use them for design, billing or contract decisions.