Evaluate both supported linear models at the same reference condition rather than mixing weather years.

Snorm=ab+bb×X−(ar+br×X)S_{\text{norm}} = a_{b} + b_{b} \times X - \left(a_{r} + b_{r} \times X\right)

Calculator

Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.

kWh
kWh/unit
kWh
kWh/unit
unit
kWh

Worked example

Given

  • aba_{b} = 40,000 kWh
  • bbb_{b} = 18 kWh/unit
  • ara_{r} = 35,000 kWh
  • brb_{r} = 12 kWh/unit
  • XX = 5,000 unit
Snorm=40,000+18×5000−(35,000+12×5000)=35,000S_{\text{norm}} = 40{,}000 + 18 \times 5000 - \left(35{,}000 + 12 \times 5000\right) = 35{,}000

Symbols and units

SymbolMeaningUnit
SnormS_{\text{norm}}normalized energy savingskWh
aba_{b}baseline interceptkWh
bbb_{b}baseline slopekWh/unit
ara_{r}reporting interceptkWh
brb_{r}reporting slopekWh/unit
XXcommon reference independent variableunit

Related calculators