Avoided cost of lossy load shifting calculator

Net energy-charge savings is calculated as E_on × r_on − (E_on/η) × r_off. Use the stated system boundary and matching input units.

S=Eon×ron−Eonη×roffS = E_{\text{on}} \times r_{\text{on}} - \frac{E_{\text{on}}}{\eta} \times r_{\text{off}}

Calculator

Enter the values you know and leave one box empty. Calculate finds the empty one, the result or any input.

kWh
$/kWh
$/kWh
—
$

Worked example

Given

  • EonE_{\text{on}} = 100 kWh
  • ronr_{\text{on}} = 50 $/kWh
  • roffr_{\text{off}} = 33.33333333 $/kWh
  • η\eta = 0.8 —
S=100×50−1000.8×33.33333333≈833.3S = 100 \times 50 - \frac{100}{0.8} \times 33.33333333 \approx 833.3

Symbols and units

SymbolMeaningUnit
SSnet energy-charge savings$
EonE_{\text{on}}avoided on-peak energykWh
ronr_{\text{on}}on-peak price$/kWh
roffr_{\text{off}}off-peak price$/kWh
η\etadelivered energy divided by charging energy—

Related calculators

Results are estimates for study and screening. Check the inputs, units and assumptions before you use them for design, billing or contract decisions.